Imaging and radiology equipment
Imaging equipment fails expensively and degrades quietly. Output drifts, image quality falls off gradually enough that nobody notices, and patient dose rises to compensate. We maintain X-ray, mammography, ultrasound and C-arm installations across India and carry out the measurements that catch the drift.

Equipment covered
Supplied, installed, maintained and repaired. Anything that measures or delivers a quantity is calibrated and documented at every visit.
- 01X-ray machine 300 mA
- 02Mammography unit
- 03CT scanner
- 04Ultrasound and sonography
- 05Echocardiography machine
- 06C-arm image intensifier
How this department is supported
Maintenance contracts
AMC and CMC cover with scheduled preventive visits and calibration at documented intervals.
Contract ScopeBreakdown repair
On-site diagnosis, with workshop support at Dudheswar for component-level restoration.
Repair ProtocolsSupply & installation
Equipment supplied, installed, commissioned and calibrated, then maintained by the same engineers.
Request QuotationQuestions we get about imaging & radiology
Not answered here? Call +91 98250 70790 and speak to someone who works on the equipment.
01Our images have got grainy over the last year. Is the machine failing?
Gradual loss of image quality is usually tube ageing or, on a C-arm, image intensifier degradation, and it is measurable rather than a matter of opinion. Output, kVp accuracy and timer are checked against reference instruments. Grain often accompanies rising dose, which is why this is worth measuring rather than adjusting around.
02Can an ultrasound probe be repaired?
Cable breaks, connector faults and housing damage are repairable. Crystal delamination in the array is generally not, and a probe with dropout across elements needs replacement. We assess the probe before quoting so you are not paying for a repair that will not restore the image.
03Do you handle AERB requirements?
We carry out the equipment side (output and kVp accuracy, timer, beam alignment, collimation and the associated records) and we advise on shielding and layout during installation. Licensing and regulatory submissions are the institution`s responsibility, and we provide the equipment data those submissions need.
04Is CT scanner service within your scope?
We handle installation support, chiller and cooling, power and environment, mechanical and console faults, and preventive routines. Tube and detector replacement runs through the manufacturer channel, and we coordinate it rather than pretending otherwise.
Laboratory equipment
Discuss your equipment
requirements.
Contract quotations follow a precise site inspection and equipment audit, not a phone call. Contact us to schedule an assessment.
Head Office
11 Vrundavan Park, Sec 22Gandhinagar 382021
Gujarat, India
Workshop
A-207, Sumel Safal-6Dudheswar, Ahmedabad 380004
Gujarat, India